Slim Size 0-10V Dimmable Driver 60W(IP67)
SMT-012-060VDSW
0-10V Dimmable Driver
SMARTS
Smarts Class 2 0-10V dimmable 60w led power supply 12v With excellent LED dimming performance, high efficiency, superior durability With 7 years warranty.
model
SMT-012-060VDSW
SMT-024-060VDSW...
Smarts Class 2 0-10V dimmable 60w led power supply 12v With excellent LED dimming performance, high efficiency, superior durability With 7 years warranty.
| model | SMT-012-060VDSW | SMT-024-060VDSW | |
| Output | DC Voltage | 12VDC | 24VDC |
| Voltage Accuracy | ±5% | ±5% | |
| Rated current | 5.0Amp | 2.5Amp | |
| Rated power | 60W | 60W | |
| Voltage Regulation | ±0.5% | ||
| Load Regulation | ±1% | ||
| Input | Voltage Range | 100-277VAC | |
| Frequency Range | 47~63HZ | ||
| Power Factor ( Typ.) | 0.99@120VAC 0.95@277VAC | ||
| THD(Typ. ) @ full load | <10%@120VAC <15%@277VAC | ||
| Full Load Efficiency(Typ.) | 84%@120VAC ,86%@277VAC | 83%@120VAC ,85%@277VAC | |
| AC Current(Typ.) | 0.9A | ||
| Inrush Current(Typ.) | 11A,50%,1ms@120VAC; 27A,50%,960us@277V | ||
| Leakage current | <0.5mA | ||
| Protection | Short Circuit | Hiccup mode, recovers automatically after fault condition is removed. | |
| Over Loading | ≤120% shut down o/p voltage, re-power on to recover | ||
| Over temperature | 100℃±10℃ shut down o/p voltage, automatically recover after cooling. | ||
| Environment | Working TEMP. | -40~+60℃ | |
| Working Humidity | 20~95%RH,non-condensing | ||
| Storage TEM.,Humidity | -40~+80℃,10~95%RH | ||
| TEMP.coefficient | ±0.03%/℃(0~50℃) | ||
| Vibration | 10~500Hz, 5G 10min./1 cycle,period for 60min. each along X,Y,Z axes | ||
| Safety&EMC | Safety standards | UL8750 +UL 1310, CAN/CSA-C22.2 No.250.13 | |
| Withstand voltage | I/P-O/P:1.88KVac | ||
| Isolation resistance | I/P-O/P:100MΩ/500VDC/25℃/70%RH | ||
| EMC EMISSION | FCC 47 CFR Part 15 ,Subpart B | ||
| EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,,11, , Alight industry level | ||
| Others | Weight | 0.45Kg | |
| Size | 300*32*20mm (L*W*H) | ||
| packing | 330*270*160mm/ 30pcs /CTN | ||
| Notes | 1. All parameters NOT specially mentioned are measured at 110VAC, 277VAC input , | ||
| Rated load and 25℃of ambient temperature. | |||
| 2. Tolerance:includes set us tolerance,line regulation and load regulation . | |||
| 3. The power supply is considered as a component that will be operated in combination with final Equipment. Since EMC performance will be affected by the complete installation, the final equipment manufactures must be-qualify EMC Directive on the complete installation again. | |||

?