DALI 2 & PUSH Dim J-BOX Driver 30W (DT6)
smarts power dali-2 & push dimmable led driver 30W integrates the power supply and terminal box into one. It passes the dali-2 dimming protocol IEC62386 and the constant voltage working mode. The working efficiency is as high as 85%. Input voltage is 100-277vac, dimming range is 0-100%
Model | SMT-JB12030V-DP2 | SMT-JB24030V-DP2 | SMT-JB36030V-DP2 | SMT-JB48030V-DP2 | |
Certificate | UL/cUL/ FCC/ SELV / CE | ||||
Output | DC Voltage | 12V | 24V | 36V | 48V |
Voltage Tolerance | ±0.5V | ||||
Voltage Regulation | ±0.5% | ||||
Rated current | 2.5A | 1.25A | 0.833A | 0.625A | |
Rated power | 30W | ||||
Load Regulation | ±2% | ±1% | ±1% | ±1% | |
Input | Voltage Range | 100-277VAC | |||
Frequency Range | 47 - 63Hz | ||||
Power Factor (Typ.) @ full load | PF≥0.98@120VAC PF≥0.95@230VAC PF≥0.90@277VAC | ||||
Efficiency(Typ.) @ full load | 82%@120VAC/60Hz 84%@230VAC/50Hz 84%@277VAC/60Hz |
82%@120VAC/60Hz 84%@230VAC/50Hz 84%@277VAC/60Hz |
82%@120VAC/60Hz 84%@230VAC/50Hz 84%@277VAC/60Hz |
82%@120VAC/60Hz 84%@230VAC/50Hz 84%@277VAC/60Hz |
|
No load power≤1.0W | ≤0.75W@120VAC/60Hz ≤0.64W@230VAC/50Hz ≤0.67W@277VAC/60Hz |
≤0.85W@120VAC/60Hz ≤0.69W@230VAC/50Hz ≤0.73W@277VAC/60Hz |
≤0.87W@120VAC/60Hz ≤0.75W@230VAC/50Hz ≤0.78W@277VAC/60Hz |
≤0.88W@120VAC/60Hz ≤0.73W@230VAC/50Hz ≤0.74W@277VAC/60Hz |
|
Standby power≤0.6W | ≤0.33W@120VAC/60Hz ≤0.43W@230VAC/50Hz ≤0.49W@277VAC/60Hz |
≤0.33W@120VAC/60Hz ≤0.44W@230VAC/50Hz ≤0.52W@277VAC/60Hz |
≤0.39W@120VAC/60Hz ≤0.45W@230VAC/50Hz ≤0.55W@277VAC/60Hz |
≤0.33W@120VAC/60Hz ≤0.44W@230VAC/50Hz ≤0.55W@277VAC/60Hz |
|
AC Current (Max.) | 0.42A | ||||
Surge current | 9.2A,180us@50%Ipeak@120VAC; 22.8A,126us@50%Ipeak@230VAC; 20.4A,200us@50%Ipeak@277VAC | ||||
Leagkage current | <0.5mA | ||||
Protection | Over Load | ≤120% ,hiccup mode, recover automatically after fault condition is removed | |||
Over temperature | Ambient temp. over 55℃±10℃, output will be off; recovers automatically after temp. drops. | ||||
Over Load | ≤120% ,hiccup mode, recover automatically after fault condition is removed | ||||
Environment | Working TEMP. | -40 ~ +70℃ (see below derating curve) | |||
Working Humidity | 20 ~ 95%RH,non-condensing | ||||
Storage TEM.,Humidity | -40 ~ +80℃,10 ~ 95%RH | ||||
TEMP.coefficient | ±0.03%/℃(0 ~ 50℃) | ||||
Vibration | 10 ~ 500Hz, 2G 10min./1 cycle,period for 60min. each along X,Y,Z axes | ||||
Safety & EMC | Safety standards | EN61347-1 EN61347-2-13(EU) & UL8750(US) & UL1310 | |||
Withstand voltage | I/P-O/P:3.75KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC (EU) I/P-O/P:1.80KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC (US) |
||||
Isolation resistance | I/P-O/P:100MΩ/ 500VDC/ 25℃/ 70%RH | ||||
EMC Emission | EN55015 EN61000-3-2-3(EU)≥50% Load & FCC Part 15 B (US) | ||||
Others | Net Weight | 0.23Kg | |||
Dimension | 181*103.5*41.7mm(L*W*H) | ||||
Packing | 250*190*135mm 20pcs /CTN | ||||
Notes | 1.All parameters NOT specially mentioned are measured at 120VAC input, rated load and 25℃of ambient temperature. 2.Under low input voltage, reduced output is required to ensure a long life. |