ELV/Triac Dimmable J-BOX Electronic Transformer 180W
180W triac dimming led driver constant voltage working mode, work efficiency reached 87%, built-in PFC function, PF value up to 0.98, electronic transformer and junction box integrated design, easy to install
Model Number | SET-12180J |
Output Type | |
Reted Power | 60W * 3 |
Reted Voltage | 12V |
Reted Current | 5A * 3 |
Voltage Tolerance | ±0.5V |
Voltage Regulation | ±0.5% |
Load Regulation | ±1% |
Input Type | |
Voltage Range | 120V |
Frequency Range | 47-63HZ |
Efficiency(Typ.) | 87%@120VAC |
Total Harmonic Distortion | THD< 20%(@100% load) |
Power Factor(typ.) | 0.98@120VAC |
AC Current(Typ.) | 1.74A |
Inrush Current(Typ.) | - |
Leakage Current | <0.5mA/ 120VAC |
PROTECTION | |
Short Circuit | Hiccup mode, recovers automatically after fault condition is removed. |
Over Load | Hiccup mode, recovers automatically after fault condition is removed. |
ENVIRONMENT | |
Working Temp. | Tcase=-40 ~ +60 (Please refer to“OUTPUTLOAD vs TEMPERATURE”section) |
Working humidity | 20 ~ 95% RH non-condensing |
Storage temp., Humidity | -40 ~ +90, 10 ~ 95% RH |
Temp .coefficient | ±0.03%/℃(0~50℃) |
Vibration | 10~500Hz, 5G 10min./1 cycle,period for 60min. each along X,Y,Z axes |
SAFETY & EMC | |
Safety standards | UL8750, Class 2 |
Safety standards | I/P-O/P:1.88KVAC |
OTHERS | |
Dimension | 7.40x4.74x1.65 inch (L*W*H) |
Packing | - |
Mounting
1.This driver must be installed in a well-ventilated area free from explosive gases and vapors. Air circulation is essential for heat dissipation.
2.Recommended spacing between LED drivers should be a minimum of 4” (10cm).
3.Do not mount driver close to or above objects that can radiate heat. Vertical mounting is highly recommended.
4.Select an appropriate location that is able to support the weight of the product.
5.Use the mounting tabs on the left and right side of the driver to mount the product.
ConnectionPreparation
InputConnections & Grounding
OutputConnections
Wiring Diagram