Slim Size Non-Dimmable LED Driver 30W (IP20)
SMT-012-030VWSP
Non-dimmable LED Driver
SMARTS
SMT-024-030VWSP Passed UL, Class 2, Class P, CE, ROHS certification slim size led driver strip power supply 12v 30w Suitable for the North American market.7-year warranty.
model
SMT-012-030VWSP
...
SMT-024-030VWSP Passed UL, Class 2, Class P, CE, ROHS certification slim size led driver strip power supply 12v 30w Suitable for the North American market.7-year warranty.
model | SMT-012-030VWSP | SMT-024-030VWSP | |
Output | DC Voltage | 12VDC | 24VDC |
Voltage Accuracy | ±5% | ±5% | |
Rated current | 2.5Amp | 1.25Amp | |
Rated power | 30W | 30W | |
Voltage Regulation | ±0.5% | ||
Load Regulation | ±1% | ||
Input | Voltage Range | 100-277 VAC | |
Frequency Range | 47~63HZ | ||
Power Factor ( Typ.) | 0.99@120VAC 0.98@230VAC 0.95@277VAC | ||
THD(Typ.)@ full load | <15%@120VAC <20%@230VAC <20%@277VAC | ||
Full Load Efficiency(Typ.) | 82%@120VAC ; 83%@230VAC; 84%@ 277VAC | ||
AC Current(Typ.) | 7A, 50%, 420us @120VAC ; 30A,50% 90us@230VAC; 12A,50%480us@277VAC |
||
Leakage current | <0.50mA | ||
Protection | Short Circuit | Hiccup mode, recovers automatically after fault condition is removed. | |
Over Loading | ≤120% shut down o/p voltage, re-power on to recover | ||
Over temperature | 100℃±10℃ shut down o/p voltage, automatically recover after cooling. | ||
Environment | Working TEMP. | -40~+60℃ | |
Working Humidity | 20~90%RH,non-condensing | ||
Storage TEM.,Humidity | -40~+80℃,10~95%RH | ||
TEMP.coefficient | ±0.03%/℃(0~50℃) | ||
Vibration | 10~500Hz,2G 10min./1 cycle,period for 60min.each along X,Y,Z axes | ||
Safety&EMC | Safety standards | EN61347-1 EN61347-2-13 | |
Withstand voltage | I/P-O/P:3.75KVAC | ||
Isolation resistance | I/P-O/P:100MΩ/500VDC/25℃/70%RH | ||
EMC EMISSION | Compliance to EN55015,EN61000-3-2 (≥60%load) | ||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,11, EN61547, light industry | ||
Others | Weight | 0.20Kg | |
Size | 260*32*18mm (L*W*H) | ||
packing | 50PCS/CTN | ||
Notes | 1. All parameters NOT specially mentioned are measured at 110VAC, 277VAC input ,Rated load and 25℃of ambient temperature. | ||
2. Tolerance:includes set us tolerance,line regulation and load regulation . | |||
3. The power supply is considered as a component that will be operated in combination with final Equipment. Since EMC performance will be affected by the complete installation,the final equipment manufactures must be-qualify EMC Directive on the complete installation again. |